6/19 Measuring technique TRUE RMS L x W x H [mm] 210 x 76 x 34 Article no. 4000 828 949 EUR 459,00 CK WB05 Leakage current clamp CM 9-1 4-digit illuminated LCD display (6,000 points) · Measurement of leakage, differential Protective conductor and load currents in electrical installations, equipment and machines · Measurement without shut-down under normal operating conditions · Ideal for preventive maintenance and troubleshooting (e.g. protection against property damage, personal injury, and power failures) · Reliable and easy detection of insulation defects (e.g. defective cables, loose terminals, soiling, and moisture) · Frequency characteristics in accordance with EN 61557-16 for testing electrical equipment pursuant to VDE 0701-0702 · LPF (low pass filter) (40–70 Hz) for suppressing high-frequency interference signals · Frequency range for rail and industry: 15 Hz–1 kHz (fg) · Defined protection against external magnetic fields in accordance with EN 61557-13, class 2 ≤ 30 A/m · Automatic range selection · Peak value (PEAK), measured value memory (HOLD) · Zero adjustment (ZERO) · Clamp opening: Max. 23 mm · Measurement category CAT IV 300 V, CAT III 600 V Measuring ranges: Alternating current (0.010 mA–60 A), maximum resolution of 1 µA in the 6 mA measuring range, voltage (0.01 V–600 V AC/DC), resistance (0.1 Ω–600 kΩ), continuity testing Scope of supply: Supplied with bag, measuring cables, batteries (2 x type AAA), for replacement batteries see article no. 4000 901 810 Unless otherwise stated, delivery without content/ accessories. The offers are only valid for commercial customers. All prices excluding VAT. Hand tools Opening of pliers [mm] 42 Measuring technique TRUE RMS L x W x H [mm] 254 x 86 x 48 Article no. 4000 828 955 EUR 389,00 CK WB05 Clamp-on ammeter multimeter CM 10-1 Illuminated 4-digit digital LCD display (6,000 pixels) · For professional use in industry, service and trade · Continuity testing · Diode testing · Data logger and memory function (4,000 measured values) · Bluetooth® Low Energy 4.0 interface for transferring measured values · Free IOS and Android app BENNING MM-CM Link for downloading, storing and sharing measured values via smartphone/tablet. AutoV function with low impedance (LoZ) for suppressing reactive voltages · Inrush current measurement (INRUSH) · Low pass filter (HFR high-frequency suppression, 800 Hz) for measurements on cycled motor drives · Measurement input for flexible current transformer BENNING CFlex 1 bis 3,000 A AC (optional accessory) · Volt sensor for contactless phase and cable break testing (red LED) · Automatic measuring range selection, shut-off, battery undervoltage display · Current value memory - Hold · Minimum/maximum value memory (MIN/MAX) · LED measuring point illumination · Measuring circuit category Cat IV 600 V, Cat III 1,000 V Measuring ranges: Alternating voltage (0.1 V–1,000 V), direct voltage (0.1 mV–1,000 V), alternating/direct current 0.01 A–1,500 A, resistance 0.1 Ω–600 kΩ, frequency 0.01 Hz–10 kHz, capacitance 0.1 μF–1 mF Supplied with bag, measuring lines, batteries (2 x type AA) For replacement battery, see article 4000 901 811 Opening of pliers [mm] 23 Measuring technique TRUE RMS L x W x H [mm] 206 x 76 x 33.5 Article no. 4000 828 923 EUR 355,00 CK WB05 Clamp-on ammeter multimeter CM 11 Illuminated 4-digit LCD display (6,000 pixels) · Precise measurement of small AC/DC currents with the highest resolution of 0.1 mA · Ideal for fault finding in electrical systems, control units, devices, and vehicle electronics · Fault finding and quiescent current measurement in fire alarm and burglar alarm systems · Measurement of differential currents and leakage currents · Measurement of 4 mA–20 mA process signals without interrupting the current loop · Quiescent current measurements on vehicle batteries for checking creeping battery discharge · Precise measurement of load currents up to 20 A AC / 10 A DC · Continuity testing · Automatic shut-down (APO after 15 min, can be de-activated) · Battery low voltage indicator · Measured value memory (HOLD), minimum/maximum value memory (MIN/MAX), ZERO function · Measurement category CAT IV 300 V, CAT III 600 V Measuring ranges: Direct current: 0.1 mA–10 A (measuring ranges 300.0 mA / 3.000 A / 10.00 A) Alternating current: 0.1 mA–20 A (measuring ranges 300.0 mA / 3.000 A / 20.00 A) Voltage: 0.01 V–600 V, resistance: 0.1 Ω–600 kΩ Supplied with batteries (2 x type AAA), measuring leads and bag, replacement batteries see article no. 4000 901 810 Opening of pliers [mm] 33 Measuring technique TRUE RMS L x W x H [mm] 243 x 103 x 55 Article no. 4000 828 943 EUR 409,00 CK WB05 Clamp-on ammeter multimeter CM 12 With logging function and Bluetooth® interface 4-digit illuminated LCD display (9,999 pixels) with bar graph · Enhanced current measuring range via the optional flexible AC current clamp adapter BENNING CFlex 1, (optional accessory - not included in the scope of supply), alternating current range 300.0 A/ 3,000 A · LOG data logger function (9,999 measured values, scanning rate: 1 s–10 min.) · MEM memory function (1,000 measured values, automatic A-SAVE storage function) · Interface: Bluetooth® Low Energy 4.0 · Free IOS and Android app for online transmission and download of the data logger/memory · Performance analysis in single-phase, three-phase and DC grids · Inrush current measurement (INRUSH) of engines and lighting systems · Deep pass filter (HFR high-frequency suppression) for measurements on motor drives · THD measurement (total harmonic distortion) · Integrated volt sensor signals non-contact phase voltages and cable breaks in lines (optical) · Automatic memory and function selection · Automatic shut-down (APO after 15 min, can be de-activated), battery low voltage indicator · Measured value memory (HOLD), max., min., average value memory (MAX/MIN/AVG), peak value memory (PEAK-HOLD) · Measurement category CAT IV 600 V, CAT III 1000 V Measuring ranges: Direct current (10 mA–600 A/measuring ranges 99.99 A/ 599.9 A), alternating current (10 mA–600 A/measuring ranges 99.99 A/ 599.9 A), voltage (10 mV–1,000 V), resistance (0.1 Ω–100 kΩ), frequency 0.01 Hz–10 kHz, capacitance 1 nF–4 mF, active power measurement 1 W–600 kW, power factor cos phi 0.01–1.00, inrush current measurement (INRUSH), THD measurement, phase sequence indicator, continuity testing (30 Ω–100 Ω), diode testing (1.8 V) Supplied with bag, batteries (6 x 1.5 V micro) and measuring leads, for replacement batteries see article no. 4000 901 810
RkJQdWJsaXNoZXIy ODY1MjQ=