6/16 Measuring technique Article no. EUR CK RMS 4000 828 865 119,00 WB05 Multimeter MM 2 With 3½-digit LCD display (2,000 points) · With polarity and battery low voltage indicator · Automatic switch-off · Continuity and diode testing · CAT III 600 V, CAT II 1000 V Measuring ranges: Direct voltage: 0.1 mV–1,000 V, alternating voltage: 0.1 mV–750 V, direct current: 0.1 µA–20 A, alternating current: 0.1 µA–20 A, resistance: 0.1 Ω–20 MΩ Supplied with protective frame, battery (1 x type block battery), measuring leads, and instrument case; replacement battery, see article no. 4000 901 814 Measuring technique Article no. EUR CK RMS 4000 828 867 155,00 WB05 Multimeter MM 3 With 3½-digit LCD display (2,000 points) · With polarity and battery low voltage indicator · Automatic switch-off · Continuity and diode testing · CAT III 300 V, CAT II 600 V Measuring ranges: Direct voltage: 0.1 mV–600 V, alternating voltage: 0.1 mV–600 V, direct current: 0.1 µA–20 A, alternating current: 0.1 µA–20 A, resistance: 0.1 Ω–20 MΩ, capacitance: 1 pF–200 µF, frequency: 1 Hz–200 kHz Supplied with protective frame, battery (1 x 9 V block battery), measuring leads, and instrument case; replacement battery, see article no. 4000 901 814 Measuring technique Article no. EUR CK RMS 4000 828 875 165,00 WB05 Multimeter MM 4 3¾-digit LCD display (4,200 points) and current clamp attachment · With polarity and battery low voltage indicator · Automatic and manual range switching · With integrated measured value memory · Automatic switch-off · Continuity and diode testing · Clamp opening: Max. 30 mm · CAT III 300 V, CAT II 600 V Measuring ranges: Direct voltage: 1 mV–600 V, alternating voltage: 1 mV–600 V, alternating current: 0.1 A–300 A, resistance: 0.1 Ω–42 MΩ Supplied with batteries (2 x type AAA), measuring line set, and instrument case; replacement batteries, see article no. 4000 901 810 Measuring technique Article no. EUR CK TRUE RMS 4000 828 866 175,00 WB05 Multimeter MM 5-2 With illuminated 4-digit LCD display (6,000 points) · Microampere measuring ranges (400.0 μA DC / 4,000 μA DC) · Continuity testing via red LED and buzzer · Diode testing · Integrated volt sensor signals non-contact phase voltages and cable breaks in lines (optical) · Single-pole phase testing · Automatic range selection · Automatic switch-off · Measured value memory (HOLD), peak value memory (PMAX/PMIN), relative measurement (REL) · Measurement category CAT IV 300 V, CAT III 600 V Measuring ranges: Direct voltage: 100 µV–600 V, alternating voltage: 100 µV–600 V. Direct current: 0.1 µA–10 A, alternating current: 20 mA–10 A, resistance: 0.1 Ω–40 MΩ. Frequency: 0.01 Hz–50 kHz, capacitance: 0.01 nF–1 mF, temperature: - 40 °C to + 400 °C Supplied with batteries (2 x type AAA), measuring leads, protective rubber frame with magnetic hanger, wire temperature probe, bag; replacement batteries, see article no. 4000 901 810 Measuring technique Article no. EUR CK TRUE RMS 4000 828 936 205,00 WB05 Multimeter MM 6-2 With illuminated 4-digit LCD display (6,000 points) with bar graph · Continuity testing via red LED and buzzer · Diode testing · AutoV function for automatic AC/DC voltage detection · LoZ low input impedance for suppressing interspersed capacitative/inductive voltages · Integrated volt sensor signals non-contact phase voltages and cable breaks in lines (optical/acoustic) · Single-pole phase testing · Automatic range selection · Automatic switch-off · Measured value (HOLD), peak value memory (PEAK), relative measurement (REL) · Measurement category CAT IV 600 V, CAT III 1000 V Measuring ranges: Direct voltage: 100 µV–1,000 V, alternating voltage: 100 µV–1,000 V, direct current: 1 mA–10 A, alternating current: 20 mA–10 A, resistance: 0.1 Ω–40 MΩ, frequency: 0.01 Hz–100 kHz, capacitance: 1 nF–10 mF Supplied with protective rubber frame with magnetic hanger, bag, battery (9 V block LR 61), measuring lines Replacement battery, see article no. 4000 876 104 Measuring technique Article no. EUR CK TRUE RMS 4000 828 879 245,00 WB05 Multimeter MM 7-1 With 4-digit LCD display (6,000 points) with bar graph · Automatic range selection · Automatic switch-off · AutoV function for automatic AC/DC voltage detection and low input impedance (LoZ) for suppression of interspersed capacitive/inductive voltages · Volt sensor signals noncontact phase voltages and cable breaks in lines (optical/acoustic) · Peak value detection (PEAK), measuring (HOLD), minimum/maximum value memory (MIN/MAX) · Continuity and diode testing · Single-pole phase testing · Measurement category CAT IV 600 V; CAT III 1000 V Measuring ranges: Direct voltage: 10 µV–1,000 V, alternating voltage: 10 µV–1,000 V Direct/alternating current: 10 µA–10 A, resistance: 0.1 Ω–40 MΩ Frequency: 0.01 Hz–100 kHz, capacitance: 1 nF–10 mF, temperature: - 40 °C to + 400 °C Supplied with protective rubber frame, battery (1 x type block battery), bag, measuring leads, wire temperature sensor with adapter; Replacement battery, see article no. 4000 901 814
RkJQdWJsaXNoZXIy ODY1MjQ=