1:46 Unless otherwise stated, delivery without content/ accessories. The offers are only valid for commercial customers. All prices excluding VAT. Hand tools OVERVIEW OF THE TEST AND MEASUREMENT FUNCTIONS BENNING ST 760 set BENNING ST 755 set VDE 0701-0702,VDE 0751 BENNING ST 725 VDE 0701-0702 Display Touchscreen with Qwertz keypad Touchscreen with Qwertz keypad Graphic display Protective conductor resistance 1 mΩ - 20 Ω 1 mΩ - 20 Ω 0.05 Ω - 20 Ω Insulation resistance 0.1 MΩ - 100 MΩ 0.1 MΩ - 100 MΩ 0.1 MΩ - 20 MΩ Protective conductor/touch current via residual current and alternate leakage current processes and direct measurement 0.05 mA - 25 mA 0.05 mA - 25 mA 0.05 mA - 25 mA 0.05 mA - 25 mA 0.05 mA - 25 mA 0.05 mA - 25 mA 0.25 mA - 20 mA 0.25 mA - 20 mA 0.1 mA - 2 mA Line test RPE, RISO, test for short-circuit/continuity of outer conductor (L) and neutral conductor (N) Residual current/RCD circuit breaker Tripping time – – 30 mA + 150 mA 10 ms - 500 ms Residual current test (RCD) PRCD, RCD PRCD, RCD RCD Testing of med. elect. devices Yes Yes – Testing of welding equipment Yes – – Voltage 0.1 V - 300 V 0.1 V - 300 V 50 V - 270 V Current 0.1 A - 16 A 0.1 A - 16 A – Active/apparent power 20 W - 4000 W 20 W - 4000 W – Interface 4x USB, 1x mini USB, 1 x RJ45, 1 x SD 4x USB, 1x mini USB, 1 x RJ45, 1 x SD Micro USB Dimensions 405 x 330 x 165 mm 405 x 330 x 165 mm 270 x 115 x 55 mm Weight 6 kg 6 kg 1100 g Battery requirement – – 6 x 1.5 V Mignon AA Memory spaces ~ 100,000 (SD card) ~ 100,000 (SD card) 999 Scope of supply Software, barcode scanner, barcode labels, test badges BENNING ST 755, software, barcode scanner, barcode labels, test badges USB cable, download software on CD, bag, batteries, test, power, IEC cable Article no. 4000 828 950 4000 828 961 4000 828 856 DEVICE TESTERS The measurement categories CAT I to CAT IV CAT I Applies for measurements on circuits that are not directly connected to the mains (e.g. devices with special protection) CAT II Applies for measurements on circuits that are electrically directly connected to the low-voltage grid (e.g. household appliances) CAT III Applies for measurements in building installations (e.g. distributor, wiring, sockets, switches) CAT IV Applies for measurements at the source of the low voltage installation (e.g. meter, main connection, primary surge protectors) Distributor Meter Outbuilding - substation Underground cable No liability is accepted for misprints, incorrect technical data and figures. 6/13
RkJQdWJsaXNoZXIy ODY1MjQ=