D no stock item. Procurement takes place after receipt of order. a = delivery by carrier + = fraction of the PU possible You will find the explanation of the symbols before the index. Hand tools OVERVIEW OF THE TEST AND MEASUREMENT FUNCTIONS DIGITAL CURRENT CLAMP MULTIMETER/LEAKAGE CURRENT CLAMP INSULATION/RESISTANCE METER ACCORDINGTO STANDARD DINVDE 0100 BENNING CM 1-2 BENNING CM 1-4 BENNING CM 2 BENNING CM 2-1 BENNING CM 10-1 BENNING CM 11 BENNING CM 12 Display range 2,000 9,999 4,000 4,000 6,000 6,000 9,999 Basic accuracy 1.0% 1.0% 0.5% 2.0% 1.0% 1.0% 1.0% Voltage AC 0.1 V - 600 V 6 V - 1000 V 1 mV - 600 V 0.1 mV - 600 V 0.1 mV - 1000 V 0.01 V - 600 V 10 mV - 1000 V Voltage DC 0.1 V - 600 V 6 V - 1000 V 0.1 mV - 600 V 0.1 mV - 600 V 0.1 mV - 1000 V 0.1 mV - 600 V 10 mV - 1000 V Current AC 100 mA - 400 A 0.1 A - 200 A 100 mA - 300 A 10 mA - 400 A 10 mA - 1500 A 0.1 mA - 20 A 10 mA - 600 A Current DC - - 10 mA - 300 A 10 mA - 400 A 10 mA - 1500 A 0.1 mA - 10 A 10 mA - 600 A Resistance 0.1 Ω - 20 MΩ 1 Ω - 50 kΩ 0.1 Ω - 40 MΩ 0.1 Ω - 40 MΩ 0.1 Ω - 600 kΩ 0.1 Ω - 600 kΩ 0.1 Ω - 100 kΩ Continuity/diode Yes/ - Yes/ - Yes/ - Yes/Yes Yes/Yes Yes/ - Yes/Yes Volt sensor – – – Yes Yes – Yes MIN/MAX memory/ ZERO function HOLD HOLD – HOLD, PEAK, ZERO HOLD, MAX/ MIN ZERO HOLD, MIN/MAX, INRUSH, ZERO HOLD, MIN/ MAX, ZERO HOLD, PEAK, MAX/MIN Measurement method RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS Clamp opening 30 mm 16 mm 25 mm 27 mm 42 mm 23 mm 33 mm Measurement category CAT III 600 V CAT IV 600 V CAT III 300 V CAT IV 300 V CAT IV 600 V CAT IV 300 V CAT IV 600 V Article no. 4000 828 957 4000 828 948 4000 828 873 4000 828 956 4000 828 955 4000 828 923 4000 828 943 BENNING IT 101 Measurements according to standard DIN VDE 0100/0105 Insulation, calculation of the resulting leakage current (test voltages 50 V ... 1000 V), low-impedance resistance Display range 4,000 digit (lighting) Voltage AC/DC 0.1 V - 600 V AC/DC TRUE RMS Insulation resistance 1 kΩ - 20 GΩ Low-impedance resistance 0.01 Ω - 40 Ω Resistance 0.01 Ω - 40 kΩ Measured value memory 500 measurement results Measurement category CAT IV 600 V Additional feature Leakage current, polarisation index (PI), absorption degree (DAR), automatic discharge function, Zero comparison of measuring lines, red LED for external voltage, green LED Article no. 4000 828 900 INSTALLATIONTESTERS BENNING IT 105 BENNING IT 130 Display Graphic display (illuminated) Graphic display (illuminated) Low-impedance measurement 0.15 Ω - 199 kΩ 0.01 Ω - 2 kΩ Insulation resistance 0.20 kΩ - 199 MΩ 10 kΩ - 1000 MΩ Line impedance (L-N/L) 0.20 Ω - 1999 kΩ 0.01 Ω - 10 kΩ Loop impedance (L-PE) 0.20 Ω - 1999 kΩ 0.01 Ω - 10 kΩ Short-circuit current up to 26 kA 0.01 A - 200 kA Residual current test type AC/A/F and B/B+ Trip time ½ x, 1 x and 5 x I∆N, AUTO) Trip current (ramp) Trip time, Trip current (ramp) Touch voltage, auto testing Test current sinusoidal (AC), pulsating (A) 10/30/100/300/500 mA – Rotating field testing right/left – Rotating field – Yes Voltage (TRUE RMS), frequency 1 V - 440 V, 45 Hz - 65 Hz 1 V - 550 V, 0 Hz - 500 Hz Grounding resistance – 0.01 Ω - 2,000 Ω (via earthing set) Current (TRUE RMS) – 0.1 mA - 400 A (via pliers) Light intensity – 0.01 lux - 20 klux (via sensor) Measured value memory – up to 1,800 measurement results Interfaces – USB, RS 232 incl. software – BENNING PC-Win IT 130 Article no. 4000 828 939 4000 828 919 No liability is accepted for misprints, incorrect technical data and figures. Handsatz_Benning_S3_NEU.indd 262 13.05.22 11 6/12
RkJQdWJsaXNoZXIy ODY1MjQ=